Description
This system seamlessly integrates with gloveboxes, providing an ideal environment for analyzing sensitive materials and devices.
By combining cutting-edge technology with user-friendly design, the PD-QE empowers researchers and engineers to explore new frontiers in spectroscopy and unlock the full potential of their photodetectors.
The availability of fundamental characterization equipment for photodetectors is crucial for both developers and users of these devices.
Different application areas, such as photodiode manufacturers, fiber-optic communication system developers, solar panel manufacturers, laboratories in universities and research institutions, and quality control companies, may have additional specific needs in terms of functionality, including the desireddetection range, resolution, or adaptability to specific environmental conditions.
Conventional quantum efficiency systems face many testing challenges in novel photodetectors. Such as:
- The bias voltage cannot exceed 12V: The traditional quantum efficiency system uses a lock-in amplifier, and its withstand DC voltage cannot be too large. Therefore, in a general quantum efficiency tester, the electric bias cannot be applied to exceed 12V.
- Unable to do noise frequency analysis.
- NEP and D* cannot be measured directly.
Enlitech provides a complete solution for the new generation of photodetectors (PD), named PD-QE.
Features

High-precision measurement:
PD-QE provides high-precision measurements of EQE and IV curves, with light source instability below 1%, ensuring the accuracy and consistency of measurement results, meeting customersā expectations for high-precision measurements.
Integrated Multi-functionality:
PD-QE integrates multiple functions including EQE testing, IV curve detection, D* analysis, NEP analysis, and frequency noise spectrum analysis. This integration provides customers with a one-stop performance evaluation solution, meeting their expectations for integrated multi-functionality.
Sensitivity Testing:Ā
PD-QE is capable of measuring high-resolution photocurrent (with a resolution of up to 10^-14 A), making it suitable for testing highly sensitive photodetectors. This helps customers accurately assess the performance of detectors under low light conditions, meeting their expectations for sensitivity testing.
Wide Wavelength Range:
Ā ApplicableĀ toĀ aĀ wideĀ rangeĀ ofĀ photodetectors,Ā PD-
QEĀ deliversĀ unmatchedĀ performanceĀ testingĀ capabilities,Ā whetherĀ inĀ theĀ R&DĀ phaseĀ orĀ onĀ theĀ productionĀ line.
Excellent Beam Control Technology:
PD-QE meets the requirements for precise beam control by providing an accurate beam size control (1*1mm^2) through its beam coupling module. This allows customers to conduct precise performance tests and simulate specific application scenarios. This meets the customersā need for precise beam control, helping them to perform more accurate performance evaluations and optimizations.
Broad Bias Voltage Range:
PD-QE supports bias voltage adjustment from 20V to 200V, meeting customersā needs to test photodetectors under different voltage conditions. This helps customers to comprehensively evaluate product performance and ensure stable operation under various application conditions.
Easy to operate and maintain:
The PD-QE is designed to be user-friendly, with simple operation and low maintenance costs, meeting customersā needs for ease of use and maintenance. This helps customers save time and costs while maintaining an efficient testing process.
Customer Support and Technical Services:
PD-QE provides professional customer support and technical services to help customers quickly resolve issues during use, ensuring the stable operation of the equipment. This meets customersā needs for timely and effective support, helping them maintain an efficient testing process.
Enlitechās team of experts possesses extensive laboratory experience and technical knowledge, enabling them to guide customers in conducting precise tests both online and on-site. For instance, through detailed analysis of noise current frequency plots, Enlitech assists customers in identifying potential testing errors and optimizing test parameters, thereby enhancing the accuracy and reproducibility of their measurements.
Enlitech understands that in the field of optoelectronics, accurate testing is crucial for product development and quality control. Customers often face challenges with complex instrument calibration and unstable data when conducting tests such as noise current frequency, quantum efficiency (EQE), detectivity (D*), and noise equivalent power (NEP). Enlitech provides comprehensive solutions to address these pain points.
Metrics like EQE and D* directly impact the sensitivity and performance of photodetectors, which is particularly critical in high-tech fields such as semiconductors, communications, and aerospace. Accurate test data not only helps customers improve product quality but also reduces product development cycles and saves costs.
Enlitech
We Make Sensors Better.
The measurement wavelength can range from UV, through VIS, to NIR, meeting the measurement range for PDs made of new materials.

The PD-QE measurement system represents cutting-edge technology in multi-wavelength analysis, capable of covering a wide wavelength range from ultraviolet to near-infrared. This feature ensures that whether in basic research or high-end manufacturing, the PD-QE can provide first-class spectral analysis capabilities.
- Wide Wavelength Coverage: The measurement range extends from 300 nanometers to 1700 nanometers, allowing you to complete a wide range of spectral tests without changing equipment.
- Precise Analysis: For each measurement point, the PD-QE can provide measurement data of over 90% quantum efficiency (EQE), ensuring the accuracy of the results.
- Integrated Solution: Integrating this system into your glovebox allows you to perform precise spectral measurements under controlled conditions, without worrying about sample exposure to uncontrolled environmental conditions.
- Efficiency and Convenience: Simplify your workflow for quick and efficient measurements. The automation features of the PD-QE system mean faster measurements and more reliable results.
- Wide Range of Applications: Whether itās solar cells, photosensitive materials, or optoelectronic components, the PD-QE can help you capture the necessary spectral data to improve product performance and efficiency.
Featuring low stray light, low noise shielded dark box, and carrier fixtures.

In cutting-edge research, even the slightest noise can have a huge impact on results. Our PD-QE equipment not only features a low stray light dark box but also specially designed low noise sample fixtures and carriers, providing you with industry-leading electrical characterization measurements.
- Low Stray Light Design: Professional-grade dark box design effectively suppresses external light source interference, ensuring the true performance of photoelectric detectors under optimal conditions.
- Extremely Low Noise Sample Handling: Our sample fixtures and carriers use state-of-the-art materials and designs, significantly reducing system background noise to capture clear electrical signals.
- Precise Electrical Characterization Analysis: As shown in the Dark IV curve, the PD-QE allows you to accurately measure tiny currents from 1 microamp to picoamp levels, whether itās dark current or reverse bias current.
- Research and Industrial Applications: Whether in research or industrial applications, the high stability and accuracy of the PD-QE make it an ideal choice for measuring the performance of photoelectric detectors.
- User-Friendly Interface: With a user-friendly operating interface, the design of the PD-QE makes every measurement simple and intuitive, easily handling even the most complex measurement tasks.
Providing automatic calculation of NEP and D*.

With the rapid development of optoelectronic technology, the demand for precise measurement of photodetector performance is increasing. The PD-QE Precision Analysis System provides an unparalleled measurement solution by automatically calculating Noise Equivalent Power (NEP) and Specific Detectivity (D*).
- High Precision Measurement: The PD-QE system calculates NEP and D* with precision down to nanowatts (nW) and square root of nanowatts per centimeter-hertz (cmHz/W), allowing you to accurately assess the detectorās minimum detectable limit and overall performance.
- Wide Wavelength Range: With the ability to measure wavelengths from 300 nanometers to 1700 nanometers, the PD-QE ensures comprehensive performance evaluation in the ultraviolet, visible, and near-infrared ranges.
- Automatic Calculation: Eliminate tedious manual calculations with the PD-QEās advanced software, which automatically provides accurate NEP and D* values, enhancing your research efficiency.
- Diverse Applications: From solar cells to optical communications and beyond, the measurement capabilities of the PD-QE make it the ideal partner for research and industry collaborations.
- User-Friendly: With an intuitive interface and automated features, the PD-QE is easy to use for users of all levels, making it easy to handle even the most complex measurement tasks.
Capable of conducting IV characteristic scans under different monochromatic light intensities.
In the precise field of optoelectronic detection, understanding the performance of detectors under different light intensities is crucial. Our PD-QE system has a unique capability to perform intensity-modulated IV characteristic scans under specific monochromatic light (e.g., 530nm), providing a multidimensional performance assessment for photodetectors.
- Multidimensional Analysis: The PD-QE system provides complete current-voltage characteristic curves for detectors from low light to high light, revealing the performance of detectors under various lighting conditions.
- Customized Light Source: Users can choose different monochromatic light sources for IV scans, accurately testing the detectorās response to specific wavelength light.
- Precise Control of Light Intensity: Our system can precisely adjust light intensity, ensuring uniformity and repeatability of light source intensity during measurements.
- Performance Evaluation: Through intensity-modulated IV scans, the PD-QE can evaluate the detectorās performance in actual applications, including its sensitivity to environmental changes.
- Advanced Features: This feature is particularly suitable for advanced research and industrial applications that require evaluating detector performance under different lighting conditions.
Capable of measuring and analyzing Noise Current Frequency.

In the field of optoelectronic detection, controlling noise levels is equally important. The PD-QE system provides professional-level noise current frequency measurement and analysis capabilities, allowing researchers to accurately capture and understand the impact of noise on detector performance.
- Wide Frequency Range Analysis: From subsonic to kilohertz, the PD-QE can reveal the noise characteristics of detectors over a wide frequency range, ensuring that you can understand and optimize performance across the entire frequency band.
- Fine Resolution Analysis: Using the high-resolution capability of the PD-QE, you can observe subtle changes in noise current, accurately pinpointing possible performance bottlenecks.
- Optimized Design: This measurement is a crucial step in optimizing detector design, reducing noise levels, and improving signal-to-noise ratio.
- Data-Driven: Through in-depth analysis of noise current, the PD-QE system enables engineers and researchers to make informed design improvement decisions based on data.
- High Efficiency: The high-efficiency data processing capability of the PD-QE means faster measurement times and faster analysis speeds, speeding up your research or production.
Basic spot size of 1x1mm, suitable for new materials PDs, such as Perovskite Photodetectors and Organic Photodetectors.

In the field of optoelectronic detection, controlling noise levels is equally important. The PD-QE system provides professional-level noise current frequency measurement and analysis capabilities, allowing researchers to accurately capture and understand the impact of noise on detector performance.
- High-Precision Spot Control: The unique design of the PD-QE system allows for accurate focusing of the beam within a range smaller than 1 millimeter, providing precise optical excitation.
- Suitability for New Materials: Perovskite and organic photodetectors are highly regarded for their unique optical properties, and the PD-QE system is designed to meet the specific needs of these new materials.
- Designed for Small-Area Detectors: The measurement technology of the PD-QE provides ideal testing conditions for small-area optoelectronic detectors, particularly in material characterization and device performance studies.
- High Efficiency and Stability: Paired with advanced light sources and stable sample mounts, the PD-QE system can provide stable and consistent measurement conditions over long periods.
- Versatility: Not limited to perovskite and organic materials, the flexible design of the PD-QE system is also suitable for testing a variety of other optoelectronic detection materials.
Combining with PD-RS to provide a more comprehensive PD-related characteristics test.

In the field of optoelectronic detection, controlling noise levels is equally important. The PD-QE system provides professional-level noise current frequency measurement and analysis capabilities, allowing researchers to accurately capture and understand the impact of noise on detector performance.
- Wide Frequency Range Analysis: From subsonic to kilohertz, the PD-QE can reveal the noise characteristics of detectors over a wide frequency range, ensuring that you can understand and optimize performance across the entire frequency band.
- Fine Resolution Analysis: Using the high-resolution capability of the PD-QE, you can observe subtle changes in noise current, accurately pinpointing possible performance bottlenecks.
- Optimized Design: This measurement is a crucial step in optimizing detector design, reducing noise levels, and improving signal-to-noise ratio.
- Data-Driven: Through in-depth analysis of noise current, the PD-QE system enables engineers and researchers to make informed design improvement decisions based on data.
- High Efficiency: The high-efficiency data processing capability of the PD-QE means faster measurement times and faster analysis speeds, speeding up your research or production.
Support for common high-precision source meters, with scanning voltage reaching ±20V or higher.
In the research and development of new-generation optoelectronic materials, the PD-QE system provides a finely tuned measurement solution specifically for perovskite and organic photodetectors. Our system can generate a basic spot size of 1Ć1 millimeters, ensuring high accuracy and reproducibility of measurement results.
- High-Precision Spot Control: The unique design of the PD-QE system allows for accurate focusing of the beam within a range smaller than 1 millimeter, providing precise optical excitation.
- Suitability for New Materials: Perovskite and organic photodetectors are highly regarded for their unique optical properties, and the PD-QE system is designed to meet the specific needs of these new materials.
- Designed for Small-Area Detectors: The measurement technology of the PD-QE provides ideal testing conditions for small-area optoelectronic detectors, particularly in material characterization and device performance studies.
- High Efficiency and Stability: Paired with advanced light sources and stable sample mounts, the PD-QE system can provide stable and consistent measurement conditions over long periods.
- Versatility: Not limited to perovskite and organic materials, the flexible design of the PD-QE system is also suitable for testing a variety of other optoelectronic detection materials.
Specification
- Optical instability: < 1%
- Monochromatic light module: Wavelength
range 300-1100 nm - Spot size of the light spot coupling module:
1Ć1 mm² - Bias voltage can range from 20 V to 200 V.
- Capable of measuring high-resolution
photocurrent with a maximum resolution of
10-14 A. - Wavelength extension up to 1800 nm.
System Design

Application
- Third-generation semiconductor materials:
Photodiode/Photodetector - OPD (Organic Photodiode)
- PPD (Perovskite Photodiode)
- QDPD (Quantum Dots Photodiode)
- New type photodiodes/ photodetectors
Customer Testimonials
Ā
Publication
Peilin Liu, Shuaicheng Lu, Jing Liu, Bing Xia, Gaoyuan Yang, Mo Ke, Xuezhi Zhao, Junrui Yang, Yuxuan Liu, Ciyu Ge, Guijie Liang, Wei Chen, Xinzheng Lan, Jianbing Zhang, Liang Gao, Jiang Tang
First published: 13 December 2023 https://doi.org/10.1002/inf2.12497
⦠The EQE and responsivity spectra were measured using a quantum efficiency system (Enlitech QE-R) ranging from 400 to 1600 nm. The noise spectra were measured from 1 Hz to 100 ā¦
Reference toļ¼Quantum Dots PhotodiodećEQEćQE-R
Zuyan Chen, Tengzuo Huang, Bo Zhang, Chunyan Wu, Xuanyu Zhang, Tao Sun, Wei Xu, Kai Kang, Chaoyu Xiang, Ting Zhang and Ruifeng Li
First published: 07 Mar 2024 https://doi.org/10.1039/D3TC04746F
⦠efficiency measurement system (Enlitech QE-R). A high-definition oscilloscope (DSOS 054 A, Agilent) was utilized to assess the time response of the photodetector. Each individual ā¦
Reference toļ¼Quantum Dots PhotodiodećQE-R
Xiao Wang,Zhulu Song,Haodong Tang,Yiwen Li,Huaying Zhong,Jiufeng Wu,Weichao Wang,Simin Chen,Wenjie Zhang,Fan Fang,Junjie Hao,Dan Wu,Peter Müller-Buschbaum,Leifeng Cao,Zeguo Tang,Jun Tang,Lei Zhang,Kai Wang and Wei Chen
First published August 1, 2024 https://doi.org/10.1021/acsami.4c05201
⦠PbS quantum dots (QDs) are promising for short-wave ā¦
⦠By implementing various film and photodetector device ā¦
⦠using PD-QE and APD-QE from ENLITECH Inc. for the EQE, responsivity, ā¦
Reference toļ¼Quantum Dots PhotodiodećPD-QEćAPD-QEćEQE
Hrisheekesh Thachoth Chandran, Ruijie Ma, Zhihan Xu, Jipsa Chelora Veetil, Yongmin Luo, Top Archie Dela PeƱa, Iyappan Gunasekaran, Sudhi Mahadevan, Kuan Liu, Yin Xiao, Hao Xia, Jiaying Wu, Mingjie Li, Sai-Wing Tsang, Xinge Yu, Wen Chen, Gang Li
First published: 30 July 2024 https://doi.org/10.1002/adma.202407271
⦠It is important to note that the D* values for all polymer ternary devices reported in this work remains among the best reported values for state-of-the-art organic photodiodes, including ā¦
Reference toļ¼Quantum Dots Photodiode
Lung-Chien Chen, Sih-An Chen, Kasimayan Uma, Chih-Hsun Chiang, Jia-Xun Xie, Zong-Liang Tseng, Shun-Wei Liu
First published: 08 October 2023 https://doi.org/10.1002/adfm.202309589
⦠The EL characteristics were measured using an LQ-100R spectrometer (Enlitech) with a ā¦
⦠EQE spectra and responsivities were recorded in DC mode using a silicon-based photodetector ā¦
Reference toļ¼Quantum Dots PhotodiodećLQ-100RćEQE
Yongjie Chen, Yingqi Zheng, Jing Wang, Xuan Zhao, Guanhao Liu, Yi Lin , Yubo Yang , Lixiang Wang, Zheng Tang , Ying Wang , Yanjun Fang , Wenkai Zhang , and Xiaozhang Zhu
First published: 5 Jun 2024 https://doi.org/10.1126/sciadv.adm9631
⦠the monolithic integration of SWIR photodiodes with silicon read- ā¦
⦠semiconductors, such as colloidal quantum dots, metal-halide ā¦
⦠(QE-R, Enlitech) with standard Si and Ge photodiodes as ā¦
Reference toļ¼Quantum Dots PhotodiodećQE-R
Kuen-Wei Tsai, Min-Hsien Chen, Gajendra Suthar, Yu-Tang Hsiao, Lin-Chieh Cheng, Chuang-Yi Liao, Fang-Chung Chen, Chih-Wei Chu, Yi-Ming Chang
First published: 04 January 2024 https://doi.org/10.1002/adom.202302435
⦠of a novel SWIR photodetector utilizing quantum dots and organic ā¦
⦠Up to date, organic semiconductor-based photodiode ā¦
⦠The EQE spectra were measured by the Enlitech QE-R ā¦
Reference toļ¼Quantum Dots PhotodiodećEQEćQE-R
Yu-Ching Huang, Sheng-Fan Wang , Bo-Cheng Chen , Zih-Syuan Yang, Meng-Chi Li,
Xun-Ying Wu, Meng-Jey Youh, Hui-Yun Chou, Yu-Xen Lin, Wanchai Assavalapsakul, Arunee Thitithanyanont, Li-Chen Su
Volume 400, Part B, 1 February 2024, 134898 https://doi.org/10.1016/j.snb.2023.134898
⦠This measurement was taken using a QE-R system from Enlitech (Kaohsiung, Taiwan) and a silicon-based photodetector (model: S1337) provided by Hamamatsu. The photocurrent c ā¦
Reference toļ¼Quantum Dots PhotodiodećQE-R
Nikhil Deep Gupta, Konasamudram Sumanth, Palusa Yashwanth, K. Raghunath
, Ashwani Kumar, Kuldip Singh, Manish Mathew
First published: 22 July 2024 https://doi.org/10.1109/TED.2024.3427094
⦠region made from ZnO nanoparticles (NPs) and carbon quantum dots (MG-CQDs) over Si/ ā¦
⦠including QE, we have worked with Enlitech RCSIS 3018 QE measurement equipment. The ā¦
Reference toļ¼Quantum Dots PhotodiodećRCSIS 3018
ShortāWave Infrared Detection and Imaging Employing SizeāCustomized HgTe Nanocrystals
Binbin Wang, Huicheng Hu, Mohan Yuan, Ji Yang, Jing Liu, Liang Gao, Jianbing Zhang, Jiang Tang, Xinzheng Lan
First published: 21 February 2024 https://doi.org/10.1002/smtd.202301557
⦠processed semiconductors, colloidal quantum dots (CQDs) ā¦
⦠statistics data across twenty photodiode devices (Figure S17, ā¦
⦠efficiency measurement system (Enlitech QE-R) light source ā¦
Reference toļ¼Quantum Dots PhotodiodećQE-R
Jing Liu, Peilin Liu, Tailong Shi, Mo Ke, Kao Xiong, Yuxuan Liu, Long Chen, Linxiang Zhang, Xinyi Liang, Hao Li, Shuaicheng Lu, Xinzheng Lan, Guangda Niu, Jianbing Zhang, Peng Fei, Liang Gao & Jiang Tang
Published: 02 September 2023 https://doi.org/10.1038/s41467-023-40620-3
⦠image using the same photodetector and circumventing the ā¦
⦠fusion utilizing colloidal quantum dots photodiode array, with a ā¦
⦠The colloidal quantum dots photodiode array showed a ā¦
Reference toļ¼Quantum Dots Photodiode
High-performance colloidal quantum dot photodiodes via suppressing interface defects
Shuaicheng Lu,Peilin Liu,Junrui Yang,Shijie Liu,Yang Yang,Long Chen,Jing Liu,Yuxuan Liu,Bo Wang,Xinzheng Lan,Jianbing Zhang,Liang Gao, and Jiang Tang
Published: February 27, 2023 https://doi.org/10.1021/acsami.2c22774
⦠PbS colloidal quantum dot (CQD) infrared photodiodes have ā¦
⦠layer (ETL) of PbS CQDs infrared photodiodes. However, ZnO-based ā¦
⦠of PbS CQDs infrared photodiode via diminishing the ā¦
Reference toļ¼Quantum Dots Photodiode
Mengqiong Zhu, Yuanbo Zhang, Shuaicheng Lu, Zijun Wang, Junbing Zhou, Wenkai Ma, Ruinan Zhu, Guanyuan Chen, Jianbing Zhang, Liang Gao, Jiancan Yu, Pingqi Gao & Jiang Tang
Published: 15 June 2023 https://doi.org/10.1007/s12200-023-00069-0
⦠In contrast, lead sulfide colloidal quantum dots are promising materials for 1550 nm IRPCs with the advantages of bandgap tuning, high absorption coefficient, and solution processing [ ā¦
Reference toļ¼Quantum Dots Photodiode
TexSe1āx Photodiode Shortwave Infrared Detection and Imaging
Liuchong Fu, Yuming He, Jiajia Zheng, Yuxuan Hu, Jiayou Xue, Sen Li, Ciyu Ge, Xuke Yang, Meng Peng, Kanghua Li, Xiangbin Zeng, Jinchao Wei, Ding-jiang Xue, Haisheng Song, Chao Chen, Jiang Tang
First published: 27 March 2023 https://doi.org/10.1002/adma.202211522
⦠, and HgTe) colloidal quantum dots (CQDs) have flexibly ā¦
⦠and can be assembled into photodetector by low-temperature ā¦
⦠and a quantum efficiency measurement system (Enlitech QE- ā¦
Reference toļ¼Quantum Dots PhotodiodećQE-R
Sensitive photodetection below silicon bandgap using quinoid-capped organic semiconductors
Tengfei Li , Gangjian Hu , Liting Tao , Jizhong Jiang, Jingming Xin, Yawen Li , Wei Ma , Liang Shen , Yanjun Fang , and Yuze Lin
Published 29 Mar 2023 https://doi.org/10.1126/sciadv.adf6152
⦠like metal halide perovskites and quantum dots, only organic ā¦
⦠The photodiode-type NIR OPDs based on our designed NIR- ā¦
⦠mW cm ā2 using a solar simulator (Enlitech model SS-F5-3A) ā¦
Reference toļ¼Quantum Dots PhotodiodećSS-F5-3A
Multifunctional and Multicolor Perovskite-CdSe Quantum Dots Diodes for Pulse Oximetry
Ting Zheng,Mingchao Zhu,Xi Luo,Fanghao Ye,Ming Wang,Yang He,Yitong Zhang,Zhenwei Lin,Zhiqing Zhang,Xu Ping,Hang Zhou,Lei Lu, and Guijun Li
Publication Date: April 19, 2023 https://doi.org/10.1021/acsami.3c01891
⦠(Enlitech, SS-F5ā3A). The photocurrent responses at different wavelengths were recorded using an EnliTech ā¦
⦠diode combined with a commercial photodetector to perform the function of ā¦
Reference toļ¼Quantum Dots PhotodiodećSS-F5ā3A
Darshan H. Parmar,Benjamin Rehl,Ozan Atan,Sjoerd Hoogland, and Edward H. Sargent
First published: December 12, 2023 https://doi.org/10.1021/acsami.3c14611
⦠Excess and deficient ligand concentrations are both detrimental to photodetector performance, yet our ā¦
⦠We believe these findings will lead to a more precise tuning of CQD photodetector ā¦
Reference toļ¼Quantum Dots Photodiode
Ji Yang,Yifei Lv,Ziyang He,Binbin Wang,Shiwu Chen,Feng Xiao,Huicheng Hu,Mengxuan Yu,Huan Liu,Xinzheng Lan,Hsien-Yi Hsu,Haisheng Song, and Jiang Tang
Published: January 9, 2023 https://doi.org/10.1021/acsphotonics.2c01145
⦠Colloidal quantum dots (CQDs) provide a high potential ā¦
⦠Here, we develop a new pāiān photodiode from the traditional p ā¦
⦠nm was obtained by a QE-R (Enlitech Co., Ltd.). For longer ā¦
Reference toļ¼Quantum Dots PhotodiodećQE-R
Infrared photodetectors and image arrays made with organic semiconductors
Zhi-Ming Zhong, Feng Peng, Lei Ying, Zhen-Qiang Huang, Wen-Kai Zhong, Gang Yu, Yong Cao & Fei Huang
Published: 18 April 2023 https://doi.org/10.1007/s10118-023-2973-8
⦠photodiodes can also be made from other semiconductors including lowband-gap organic semiconductors[12ā14] and quantum dots ā¦
⦠measurement systems: QE-R (Enlitech Co., Ltd.) ā¦
Reference toļ¼Quantum Dots Photodiode
Rongqing Huang, Ketai Wu, Wanjun Li, Xinyue Huang, Sitong Zhou, Shaowei Jiang, Yong Fu, Zhijuan Zhao, Wenjie Mai, Chuanxi Zhao
First published: 30 July 2023 https://doi.org/10.1002/adom.202301177
⦠A source meter (Keithley, 2601A) was used to record the photocurrent while a QE-R external quantum efficiency system (Enlitech, Si detector S10-14010) was used to record the ā¦
Reference toļ¼Quantum Dots PhotodiodećQE-R
A near-infrared colloidal quantum dot imager with monolithically integrated readout circuitry
Jing Liu, Peilin Liu, Dengyang Chen, Tailong Shi, Xixi Qu, Long Chen, Tong Wu, Jiangping Ke, Kao Xiong, Mingyu Li, Haisheng Song, Wei Wei, Junkai Cao, Jianbing Zhang, Liang Gao & Jiang Tang
Published: 16 June 2022 https://doi.org/10.1038/s41928-022-00779-x
⦠near-infrared colloidal quantum dot photodiodes with complementary metalāoxideāsemiconductor readout integrated circuits. The colloidal quantum dot photodetector is designed with ā¦
Reference toļ¼Quantum Dots Photodiode
Yibo Zhang, Joel Y. Y. Loh, Nazir P. Kherani
First published: 17 October 2022 https://doi.org/10.1002/advs.202203234
⦠available QE-R system from Enlitech (with greater than ā ā¦
⦠: Si photodetector from 300 to 1100 nm (Enlitech Model RC-S103011-E) and Ge photodetector from 1100 to 1200 nm (Enlitech ā¦
Reference toļ¼Quantum Dots PhotodiodećQE-RćRC-S103011-E
Donglin Jia, Jingxuan Chen, Junming Qiu, Huili Ma, Mei Yu, Jianhua Liu, Xiaoliang Zhang
Published:June 06, 2022 https://doi.org/10.1016/j.joule.2022.05.007
⦠The regulation of the surface ligand chemistry of perovskite quantum dots (PQDs) is critical for the construction of conductive and stable PQD solid films, thus determining the ā¦
Reference toļ¼Quantum Dots Photodiode
Keita Yoshida, Jia-Fu Chang, Chu-Chen Chueh & Tomoya Higashihara
Published: 21 January 2022 https://doi.org/10.1038/s41428-021-00597-6
⦠G and 100 mW cm ā2 illumination provided by an SS-F5-3A simulator purchased from Enlitech Co., Ltd. The illumination intensity was calibrated using a Si photodiode detector with a ā¦
Reference toļ¼Quantum Dots PhotodiodećSS-F5-3A
Guang Yang, Hengkai Zhang, Siqi Li, Zhiwei Ren, Guojia Fang, Dangyuan Lei, Gang Li
First published: 02 February 2022 https://doi.org/10.1002/smm2.1087
⦠The perovskite quantum dots are synthesized via a modified ā¦
⦠calibrated by means of a Si photodiode with a KG5 filter. The ā¦
⦠a QE-R 3011 system (Enli Tech). The photoluminescence (PL) ā¦
Reference toļ¼Quantum Dots PhotodiodećQE-R 3011
Sijing Zhong, Han Chen , Jinglin Yi , Tao Yang , Ziqi Gan , Xiaozhe Su ,Meijing Li , Zhiming Zhong , Feng Peng , Lei Ying
Volume 109, October 2022, 106610 https://doi.org/10.1016/j.orgel.2022.106610
⦠EQE of the device was tested by a commercial measurement system QE-R3011 (Enlitech Co., Ltd.). Responsivity can be calculated using R = EQE Ć Ī» 1240 ( A W ā 1 ) . Before testing, ā¦
Reference toļ¼Quantum Dots PhotodiodećQE-R3011
Zong-Liang Tseng, Yan-Siang Huang, Yi-Liang Liu,Tsung-Lin Wu, Yu-Jen Wei
Volume 897, 15 March 2022, 163182 https://doi.org/10.1016/j.jallcom.2021.163182
⦠A ligand-exchange reaction using TOAB was present for stable CsPbI 3āx Br x quantum dots ā¦
⦠measured using an LQ-100R spectrometer (Enlitech) with a computer-controlled integrating ā¦
Reference toļ¼Quantum Dots PhotodiodećLQ-100R
Kuen-Wei Tsai,Govindasamy Madhaiyan,Lai-Hung Lai,Yu-Tang Hsiao,Jhao-Lin Wu,Chuang-Yi Liao,Cheng-Hung Hou,Jing-Jong Shyue,Yi-Ming Chang
First published:August 12, 2022 https://doi.org/10.1021/acsami.2c08336
⦠The EQE spectrum was measured by the Enlitech QE-R spectrometer. The intensities of the ā¦
⦠calibration: the Si photodetector is for 300 to 1100 nm, and the Ge photodetector is for 900 to ā¦
Reference toļ¼Quantum Dots PhotodiodećEQEćQE-R
Kai-Hua Kuo,Richie Estrada,Chih-Chien Lee,Nurul Ridho Al Amin,Ya-Ze Li,Marvin Yonathan Hadiyanto,Shun-Wei Liu, and Ken-Tsung Wong
First published:April 14, 2022 https://doi.org/10.1021/acsami.2c04434
⦠On the range frequency of 300ā850 nm, the spectrum of EQE and responsivity were recorded in DC mode using QE-R systems (Enlitech, Taiwan) with Si-based photodetector ( ā¦
Reference toļ¼Quantum Dots PhotodiodećEQEćQE-R
Effect of formamidinium (FA) ions on mixed ‘A’-site based bromide perovskite (APbBr 3) thin films
Deepak Aloysius, Arindam Mondal, Satyajit Gupta, Eran Edri and Sabyasachi Mukhopadhyay
First published: 21 Oct 2022 https://doi.org/10.1039/D2NJ05052H
⦠obtained through PL for some perovskite quantum dots (QD) such as ā¦
⦠quantum efficiency) analysis was carried out using a quantum efficiency measurement system (QE-R, Enlitech ā¦
Reference toļ¼Quantum Dots PhotodiodećQE-R




Reviews
There are no reviews yet.