Description
Description
Specification
Application
Contact
Characterization Module
Optional
Installation
Publication
Description
ARS (Angular Response System) is a test system for the angular distribution characteristics of various light sensors. The system consists of a highly collimated and parallel simulated light source (divergence angle < 0.1°) that projects a high uniformity light spot with a diameter greater than or equal to 25mm onto the light sensor under test. The system is equipped with an angle test with an angle resolution of less than 0.1° and a working range of -90° to 90°. The system software can automatically draw angle distribution and light response curves, making it the best tool for developing various light sensor module structures.
- Highly collimated and parallel simulated light source (divergence angle < 0.1°)
- Projected light spot with high uniformity and a diameter greater than or equal to 25mm
- Angle testing range from -90° to +90°
- Angle resolution smaller than 0.1°
Features
- Highly collimated and parallel simulated light source (divergence angle < 0.1°)
- Projected light spot with high uniformity and a diameter greater than or equal to 25mm
- Angle testing range from -90° to +90°
- Angle resolution smaller than 0.1°
Specification
| Specification | |
|---|---|
| Light Parallelism | Divergence angle of 1° |
| Uniformity light Area | 30 mm x 30 mm >90% |
| Color Temperature | 4850K ~ 5500K |
| High Intensity | 900 ~ 1500 Lux Step:< 5 Lux |
| Median Intensity | 30 ~ 900 Lux Step:< 2 Lux |
| Low Intensity | 0 ~ 30 Lux Step:< 0.1 Lux |
| Dimension | 228mm*145mm*173mm |
| Weight | 1.9kg |
Empirical evidence
ARC angle distribution diagram

System Design
Application
Application Range
- TFT Sensor
- ALS
- FoD
- SPAD
Customer Testimonials
Contact us
SDTM、TDTM Characterization Module
(1) SDTM Spectral Characterization Module – Equipment Specifications
| SDTM Spectral Characterization Module – Equipment Specifications | |
|---|---|
| Continuous wave light source | 1.Stable light source system (xenon lamp) 2.Monochromator: 350-1100 nm, resolution 1nm, typical FWHM 10 nm; accuracy 0.6nm 3.Fiber coupling and optical diffuser: 5×5 mm or 10×10 mm beam, uniformity >99% at 25 mm working distance. (with 50 mm x 50 mm illumination spot) |
| Light source and beam delivery system | 1.Ultra-uniform silicon photodiode sensor, 10mm x 10mm active area, optically aged to eliminate instability 2.Wavelength range 350-1100nm, peak responsivity at 960nm 3.Traceable, certified calibration report to NIST (ISO 17025 certified, compliant to Spec 1) 4.Noise equivalent power of 1.5 x 10-14 W/√Hz |
| Source stage | 1.Device biasing and measurement 2.Voltage range: > 200V 3.Current range: 1.5A max. 4.Minimum resolution: 100 nV, 10 fA |
| Photon detector | 1.Resolution: 100 ps 2.Count rate: > 300 MHz 3.Input voltage range: ± 5V |
| Measurable parameters | 1.Photon detection probability over spectrum 2.Dark counts 3.External quantum efficiency over spectrum 4.Breakdown voltage 5.Spectral responsivity over spectrum |
(2) TDTM Time Domain Characterization Module
| TDTM Time Domain Characterization Module | |
|---|---|
| PS Laser | 1.Wavelength 940 nm 2.FWHM <90 ps 3.MAX rep. rate: 80 MHz (adjustable) |
| T-counter | 1.Detection Channel: 4 Chs 2.BIN Resolution: 5 ps 3.Time-tagging and time-resolved modes |
| Measurable Parameters | 1.Jitter 2.Diffusion Tail 3.Signal-to-Noise Ratio |
| controller | ●Industrial Computer ●Screen ●Keyboard and Mouse |
|---|
Publication
Optional items
| Optional items | |
|---|---|
| Probe station | 1.Three styles: fully automatic / semi-automatic / manual 2.Suitable for wafer level sample measurement 3.Please contact us |
| Customized test fixture | 1.Suitable for module type sample measurement 2.Please contact us |
| Custom camera obscura | 1.The camera obscura has a noise shielding function 2.Please contact us |




Reviews